Real and effective VMware VCAP6.5-DCV Design 3V0-624 Dumps,3V0-624 pdf download Online | 100% Latest Updates

We share the latest exam dumps throughout the year to help you improve your skills and experience! The latest VMware VCAP6.5-DCV Design 3V0-624 exam dumps, online exam Practice test to test your strength, VMware 3V0-624 “VMware Certified Advanced Professional 6.5”
in https://www.leads4pass.com/3v0-624.html Update the exam content throughout the year to ensure that all exam content is authentic and valid.
3V0-624 PDF Online download for easy learning.

[PDF] Free VMware VCAP6.5-DCV Design 3V0-624 pdf dumps download from Google Drive: https://drive.google.com/open?id=12vxSJfS8jvCd9FoKQmWCteBNsoRI1iVF

[PDF] Free Full VMware pdf dumps download from Google Drive: https://drive.google.com/open?id=1nHEmK_fnMmC9Md5GWyYqSo5-8DM9SYyD

VMware Certified Advanced Professional 6.5 – Data Center Virtualization Design Exam: https://www.vmware.com/education-services/certification/vcap6-5-dcv-design-exam.html

Free test VMware VCAP6.5-DCV Design 3V0-624 Exam questions and Answers

QUESTION 1
A customer wants to make its data available with a RPO of 10 minutes. Replication to the second data center will be
done using the network. Which type of storage configuration should be used?
A. NFS datastore on ESXi 6.0 with vSphere replication appliance 6.0
B. VMFS datastore on ESXi 6.0 with vSphere replication appliance 6.5
C. vSAN datastore on ESXi 6.0 with vSphere replication appliance 6.5
D. VMFS datastore on ESXi 6.0 with vSphere replication appliance 6.0
Correct Answer: B

QUESTION 2
What topics need to be considered when creating a storage design?
A. Application I/O requirements
B. Growth rate
C. Latency
D. All of the above
Correct Answer: D

QUESTION 3
An architect is designing a vSphere 6.5 implementation.
The customer requires Cross vCenter vMotion for the newly-created data centers in New York and Houston.
Each data center will use different IP networks for management and vMotion.
When creating a vMotion network, which two statements are required in order to use Cross vCenter Server vMotion?
(Choose two.)
A. vMotion Networks in both data centers must be in the same L2 stretched VLAN.
B. The virtual machine port groups must use the same name.
C. VMkernel port for vMotion must be configured with vMotion TCP/IP Stack with the correct gateway.
D. vMotion networks in both data centers must be routable over L3 network.
Correct Answer: CD

QUESTION 4
A solution architect has finished conducting interviews and gathering requirements for a company, and has determined
that the logical requirements are:
two data centers for high availability
synchronous replication to meet the zero minute RPO
separating management workloads from application workloads
dedicated 10Gb uplink for each low latency server
single management port for the entire environment
Which two actions would meet the design requirements? (Choose two.)
A. Create two data center objects in vCenter Server.
B. Configure vSAN Stretched Clustering.
C. Configure SR-IOV for low latency servers.
D. Create one folder for Management workloads and one folder for application workloads.
Correct Answer: BD

QUESTION 5
A company would like to leverage snapshot technology on vSphere 6.5.
Which configuration supports taking snapshots?
A. Windows Failover Cluster VM with RDM in virtual mode
B. vSphere Fault Tolerance VM
C. Windows Failover Cluster VM with RDM in physical mode
D. SQL Always On Availability Group
Correct Answer: A

QUESTION 6
A company is consolidating its IT operations efforts by moving the Finance, IT, and QA departments towards a self-
service environment, following SDDC best practices.
All departments have different priorities and expectations for uptime of the required infrastructure and applications.
Project stakeholders are still discussing final approvals for the budget wan the CFO.
To drive down the operating cost of the environment, only blade servers will implement this project.
To ensure business continuity, a colocation provider was chosen to fail over virtual machines.
The implementation of the project will follow a public reference architecture provided by VMware.
What is the assumption in this scenario?
A. The chosen architecture is sufficient.
B. All departments demand different SLAs.
C. Final budget approvals are being discussed.
D. The environment will be shared by several departments.
Correct Answer: A

QUESTION 7
Which two types of workloads are efficiently consolidated when virtualized? (Choose two.)
A. Workloads that do NOT require user input and are constantly processing large amounts of batched data.
B. Workloads that will consume all available assigned resources.
C. Workloads that are NOT CPU bound; most of their time is spent waiting for external events such as user interaction.
D. Workloads that do NOT require access to specific physical resources such as a hardware dongle or graphics card.
Correct Answer: CD

QUESTION 8
A customer has requested a high availability option for its data center in the event of power failure and the loss of
connectivity to a virtual machine.
Which three vSphere features support fault tolerance? (Choose three.)
A. HA
B. Virtual volume datastore
C. vMotion
D. Storage-based policy management
E. DRS
F. Virtual machine snapshots
Correct Answer: ACE

QUESTION 9
Customer Requirements:
You have been tasked with creating a vSphere 6.5 data center design for an organization. The organization wants three
defined virtual machine performance levels:
-Gold Tier -High workload VMs
-Silver Tier -Medium workload VMs
-Bronze Tier -Development workload VMs
The organization has eight ESXi hosts that can be used in the design. Five of the hosts are older “medium performance”
hosts, while the last 3 are newer “high performance” hosts that provide better resources when compared to the other
hosts. The organization has provided a list of requirements that the design must meet:

Gold Tier virtual machines should run only on high performance servers, unless no high performance servers are
available. They should also be allocated 75% of overall available resources regardless of placement.

Silver Tier virtual machines should run only on medium performance servers, unless no medium performance servers
are available. They should also be allocated 25% of overall available resources regardless of placement.

Bronze Tier virtual machines should run only on medium performance servers. They should also receive a 35% subset
of resources from those allocated to the Silver Tier.
Design Requirements:
Create a logical design that shows resource allocation and cluster policies needed to meet the customer\\’s
requirements. The design should include:

All required server(s)

All required resource(s)
Place host(s) in the required DRS group(s). Place virtual machines in the appropriate resource pool(s). Connect parent
to child resource pool connector(s) where needed. Connect the appropriate affinity connector(s) where needed.lead4pass 3V0-624 exam question q9 lead4pass 3V0-624 exam question q9-1 lead4pass 3V0-624 exam question q9-2 lead4pass 3V0-624 exam question q9-3 lead4pass 3V0-624 exam question q9-4

A. Check the answer in explanation.
Correct Answer: A
Check below for answer solution:

lead4pass 3V0-624 exam question q9-5 lead4pass 3V0-624 exam question q9-6 lead4pass 3V0-624 exam question q9-7

QUESTION 10
The customer has two sites that must operate independently of each other in the event of a WAN failure. During normal
operations, administrators from each site must be able to manage the other site through the vSphere Web Client.
Which vCenter Server Appliance (VCSA) and Platform Services Controller (PSC) diagram shows the VMware-
recommended design that satisfies these requirements?lead4pass 3V0-624 exam question q10 lead4pass 3V0-624 exam question q10-1

Correct Answer: D
https://www.opvizor.com/understanding-the-impacts-of-mixed-version-vcenter-server-deployments/

QUESTION 11
A solution architect has finished conducting interviews and gathering requirements for a company, and has determined
that the logical requirements are:
two data centers for high availability
synchronous replication to meet the zero minute RPO
separating management workloads from application workloads
dedicated 10Gb uplink for each low latency server
single management point for the entire environment
Which two actions would meet the design requirements? (Choose two.)
A. Configure 1 Port Group with a dedicated 10Gb Uplink for low latency servers.
B. Deploy two clusters, one for management workloads and one for application workloads.
C. Build 2 Port Groups, one for management serves and one for application servers.
D. Install two vCenter Servers in Enhanced Link Mode.
Correct Answer: AB

QUESTION 12
Customer Information The Customer Labtown has a new vSphere 5 environment with one of their line of business
applications recently being virtulized. Labtown requires that their Webserver, Database Server, and Fileserver for their
line of business app be
created into a vAPP. The VM\\’s should start up in a specific order to insure the application starts correctly after an
outage or reboot. Labtown also wants the best performance possible out of each VM. There is three hosts in the cluster
each running the same CPU and Memory specifications. each host is running at 60% utilization right now. Labtown
doesn\\’t have any budget for more hosts. Create a logical vAPP design for Labtowns Line of Business Application
Requirements
-The server must boot in the following order: DB, Fileserver, WebServer
-Each VM must perform the best it can with the current cluster configuration Instructions

Place the three VM\\’s on the vAPP

Place the boot order boxes ontop of each VM to indicate the VM\\’s boot order

Place the VM stencil for each VM in the DRS rules section if you wish to apply DRS rules to the design

As long as VM\\’s are on the vAPP stencil marks will be scored See the solution below
A.
Check the answer in explanation.
Correct Answer: A
Check below for answer solution:lead4pass 3V0-624 exam question q12

QUESTION 13
A virtualization administrator has been tasked with migrating several business applications from physical to virtual. The
administrator must also migrate the virtual machines from VMware Workstation to vSphere 6.5, using vCenter Converter
Standalone 6.1.
In this scenario, when two source types are supported? (Choose two.)
A. powered-off Windows Server 2008 physical machine
B. powered-on Windows Server 2000 Workstation virtual machine
C. powered-off Windows Server 2008 Workstation virtual machine
D. powered-on Windows Server 2008 physical machine
Correct Answer: CD

QUESTION 14
A development team must provide layer 2 network isolation between virtual machines that are in the same VLAN. The
solutions architect must provide additional security between the virtual machines on the same subnet.
How can this be done without consuming more VLANs?
A. Use Virtual Switch Tagging
B. Use Private VLANs.
C. Use Virtual Guest Tagging.
D. Use External Switch Tagging.
Correct Answer: B

We share 14 of the latest VMware VCAP6.5-DCV Design 3V0-624 exam dumps and 3V0-624 pdf online download for free. Now you know what you’re capable of! If you’re just interested in this, please keep an eye on “Allaboutexams.com” blog updates! If you want to get the VMware VCAP6.5-DCV Design 3V0-624 Exam Certificate: https://www.leads4pass.com/3v0-624.html (Total questions:89 Q&A).

Related 3V0-624 Popular Exam resources

title pdf youtube VMware Certified Advanced Professional 6.5 – Data Center Virtualization Design Exam lead4pass
VMware 3V0-624 lead4pass 3V0-624 dumps pdf lead4pass 3V0-624 youtube VMware Certified Advanced Professional 6.5 – Data Center Virtualization Design Exam https://www.leads4pass.com/3v0-624.html
VMware VCAP6.5-DCV Design       https://www.leads4pass.com/3v0-624.html

Lead4pass Promo Code 12% Off

lead4pass 3V0-624 coupon

Why Choose Lead4pass?

Lead4Pass helps you pass the exam easily! We compare data from all websites in the network, other sites are expensive, and the data is not up to date, Lead4pass updates data throughout the year. The pass rate of the exam is above 98.9%.

why lead4pass 3V0-624 exam dumps